Model Expand Primary
Nominal
Value
Measuring
Range
Secondary
Signal
Supply
Voltage (V)
Accuracy (%) Mounting
 
LF 1005-S/SP12 expand 600 A 1750 A 120 mA 24-24 Bi 0.5 Panel
  Technology : Closed loop Hall Effect  
LF 1005-S/SP14 expand 1000 A 1500 A 200 mA 24-24 Bi 0.5 Panel
  Technology : Closed loop Hall Effect  
LF 1005-S/SP33 expand 1000 A 2000 A 200 mA 24-24 Bi 0.5 Panel
  Technology : Closed loop Hall Effect  
LF 2005-S/SP1 expand 2000 A 3500 A 400 mA 15-24 Bi 0.3 Panel
  Technology : Closed loop Hall Effect  
LF 2005-S/SP11 expand 2000 A 3700 A 400 mA 15-24 Bi 0.4 Panel
  Technology : Closed loop Hall Effect  
LF 2005-S/SP13 expand 2000 A 3500 A 400 mA 15-24 Bi 0.3 Panel
  Technology : Closed loop Hall Effect  
LF 2005-S/SP3 expand 2000 A 3000 A 400 mA 15-24 Bi 0.3 Panel
  Technology : Closed loop Hall Effect  
LF 2005-S/SP4 expand 2000 A 3000 A 400 mA 15-24 Bi 0.3 Panel
  Technology : Closed loop Hall Effect  
LF 2005-S/SP8 expand 2000 A 3700 A 400 mA 15-24 Bi 0.4 Panel
  Technology : Closed loop Hall Effect  
LF 2005-S/SP9 expand 1000 A 2000 A 200 mA 24-24 Bi 0.3 Panel
  Technology : Closed loop Hall Effect  
LF 205-S/SP1 expand 200 A 420 A 100 mA 12-15 Bi 0.5 Panel
  Technology : Closed loop Hall Effect  
LF 205-S/SP5 expand 100 A 200 A 100 mA 12-15 Bi 0.5 Panel
  Technology : Closed loop Hall Effect  
LF 305-S/SP10 expand 300 A 500 A 150 mA 12-20 Bi 0.47 Panel
  Technology : Closed loop Hall Effect  
LF 305-S/SP7 expand 250 A 350 A 125 mA 15-15 Bi 0.4 Panel
  Technology : Closed loop Hall Effect  
LF 505-S/SP22 expand 500 A 1200 A 143 mA 15-24 Bi 0.6 Panel
  Technology : Closed loop Hall Effect  
LF 505-S/SP23 expand 500 A 1000 A 100 mA 24-24 Bi 0.6 Panel
  Technology : Closed loop Hall Effect